20,270 Mike Bigham Construction

By: Cal-OSHA Decisions
29 COR 40-4689 [¶ 20,270]

ELEVATOR SHAFTS - GUARDING
CAL. CODE REGS, tit. 8, § 1633(a) (2002) - Employees worked by the open side of an elevator shaft without the protection of guardrails. However, Employer proved that it could not have known of the violative condition, so the serious classification was not appropriate.

SCAFFOLDS - UNSTABLE PLANKING SUPPORT
CAL. CODE REGS, tit. 8, § 1637(j) (2002) - Employer's electrician worked from a scaffold platform that was supported at one end by an unsecured, on-edge plank, a serious violation.

SCAFFOLDS - RAILINGS