NOLTE SHEET METAL, INC.

By: Rick Waldinger

43  COR 40-7364 [¶22,561]

JURISDICTION – CONSENT TO INSPECTION
Labor Code §§ 6307, 6314(a) (2016) – The Division received valid consent from a representative of Employer to inspect its premises.

INJURY AND ILLNESS PREVENTION PROGRAM – WRITTEN PROGRAM (IIPP)
Cal. Code Regs, tit. 8, § 1509(a) (2016) – Employer failed to have a written IIPP at the time of the inspection.

LOW-VOLTAGE ELECTRICAL SAFETY ORDERS – REQUIREMENTS FOR ELECTRICAL INSTALLATIONS, MECHANICAL EXECUTION OF WORK
Cal. Code Regs, tit. 8, § 2340.12(a) (2016) – Employer failed to guard openings in its shop electrical panel.

LOW-VOLTAGE ELECTRICAL SAFETY ORDERS – REQUIREMENTS FOR ELECTRICAL INSTALLATIONS, WORK SPACE ABOUT ELECTRIC EQUIPMENT
Cal. Code Regs, tit. 8, § 2340.16(c) (2016) – Employer failed to keep the working space in front of its shop electrical panel clear.

LOW-VOLTAGE ELECTRICAL SAFETY ORDERS – FLEXIBLE CORDS AND CABLES, PULL AT JOINTS AND TERMINALS
Cal. Code Regs, tit. 8, § 2500.10(a) (2016) – Employer failed to to provide strain relief on a cord supplying power to the break in its fabrication shop.

INDUSTRIAL TRUCKS, TRACTORS, HAULAGE VEHICLES, AND EARTHMOVING EQUIPMENT –POWERED INDUSTRIAL TRUCK OPERATOR TRAINING
Cal. Code Regs, tit. 8, § 3668(a)(2) (2016) – Employer failed to ensure that each operator of its forklifts successfully completed the required training.

HEAT ILLNESS PREVENTION – TRAINING EMPLOYEES
Cal. Code Regs, tit. 8, § 3395(f)(1) (2016) – Employer failed to provide training on the risk of heat illness to employees.

HEAT ILLNESS PREVENTION – TRAINING SUPERVISORY EMPLOYEES
Cal. Code Regs, tit. 8, § 3395(f)(2) (2016) – Employer failed to provide training on risk of heat illness to supervisory employees.

HEAT ILLNESS PREVENTION – WRITTEN HEAT ILLNESS PREVENTION PROGRAM (HIPP) PROVIDED UPON REQUEST
Cal. Code Regs, tit. 8, § 3395(f)(3) (2016) – Employer failed to provide a copy of its HIPP to the Division upon request.

HAZARDOUS SUBSTANCES AND PROCESSES – WRITTEN HAZARD COMMUNICATION PROGRAM
Cal. Code Regs, tit. 8, § 5194(e) (2016) – Employer failed to develop, implement and maintain a hazardous communication program.

COMPRESSED GAS AND AIR EQUIPMENT – STORAGE, HANDLING, AND USE OF CYLINDERS, COMPRESSED GAS CYLINDERS STORED OR TRANSPORTED TO PREVENT TIPPING, FALLING OR ROLLING
Cal. Code Regs, tit. 8, § 4650(e) (2016) – Employer failed to to secure compressed gas cylinders.