SHIMMICK CONSTRUCTION CO., INC./OBAYASHI CORPORATION JV
By: Rick Waldinger
Vol: 42 | No: 35 | Published on: September 17, 2015
42COR 40-7291 [¶22,508R]
EXCAVATIONS – REQUIREMENTS FOR PROTECTIVE SYSTEMS, APPROVAL OF REGISTERED PROFESSIONAL ENGINEER (RPE) Cal. Code Regs, tit. 8, § 1541.1(c)(4) (2015) – Employer modified the protective system of a shoring pit without consulting a registered professional engineer. Employees were exposed to the violative condition. The Board upheld the violation, which was classified as willful-serious.
Digest of COSHAB’s Denial of Petition for Reconsideration dated September 3, 2015, Docket No. 12-R3D1-0781.